›› 2006, Vol. 1 ›› Issue (1): 11-14.
• 论文 • Previous Articles Next Articles
Lingdan Meng; XiaoHui Chen; Yan Yao and KaiShun Bi*
Received:
Revised:
Online:
Published:
Contact:
Abstract: A simple, rapid and reliable high-performance liquid chromatography (HPLC) method has been developed for the first time to simultaneously determine the four major ingredients, namely gallic acid, Albiflorin, paeoniflorin and ferulic acid, in an oral solution of Siwu Heji. The separation of these marker compounds was achieved on an Extend-C18 column with gradient elution using acetonitrile and aqueous phosphoric acid as the mobile phase. The assay was linear over the range (μg) 0.066-0.598 for gallic acid, 0.171-1.537 for Albiflorin, 0.220-1.982 for paeoniflorin and 0.010-0.091 for ferulic acid. The average sample recovery (%) was 101.6, 100.2, 98.8 and 99.1 for these four constituents, respectively. The results demonstrated variations in the content of each of the marker compounds in different lots, indicating that careful quality control of the bioactive ingredients in Siwu Heji is necessary to ensure the uniformity of their extraction procedures. This assay is suitable for the quality control of Siwu Heji.
Key words: Siwu Heji, gallic acid, albiforin, paeoniflorin, ferulic acid, HPLC
Lingdan Meng;XiaoHui Chen;Yan Yao and KaiShun Bi*. Simultaneous Determination of Four Main Compounds in Siwu Heji by High-performance Liquid Chromatography[J]. , 2006, 1(1): 11-14.
0 / / Recommend
Add to citation manager EndNote|Reference Manager|ProCite|BibTeX|RefWorks
URL: http://ajtm.magtechjournal.com/EN/
http://ajtm.magtechjournal.com/EN/Y2006/V1/I1/11